Hague-quality-water-intl WATERMAX 60 SERIES User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
WaterMax 60 Series Owner’s Manual 11/10/2008 20
Service Settings, Cont.
Mode 2 (Demand Delayed Mode) Setting Chart
This section provides guidance for using different service settings to achieve the desired capacity.
Note: Mode 2 and Mode 3 have the same settings. Mode 3 is NOT recommended for residential use.
60 Series 63MAQ
1
63BEQ
1,2
63MXQ
1
63MDQ
3
62AMQ
1
62APQ
1,3,4
62AKQ
3
62AJQ
3,5
Mode 2 Yes Yes Yes No Yes No No No
Capacity
As
required
As
required
As
required
As
required
— — —
96 hour regeneration
(if iron present—yes)
6
Yes or No Yes or No Yes or No Yes or No
#1 Salt Setting
Backwash 1 (minutes) 1 1 1
6
— 2
6
— — —
Brine/Rinse (minutes) 7 7 7 — 7 —
Backwash 2 (minutes) 3 3 3 2
Capacity (grains) @
salt (lb)
5,900 @
1.1 lb
5,900 @
1.1 lb
8,400 @
1.6 lb
5,200 @
1 lb
— — —
#2 Salt Setting
Backwash 1 (minutes) 1 1 1
6
— 2
6
— — —
Brine/Rinse (minutes) 12 12 19 — 12 —
Backwash 2 (minutes) 3 3 3 2
Capacity (grains) @
salt (lb)
16,300 @
3.2 lb
16,300 @
3.2 lb
20,000 @
4.2 lb
11,900 @
2.7 lb
— — —
#3 Salt Setting
Backwash 1 (minutes) 1 1 1
7
— 2
7
— — —
Brine/Rinse (minutes) 30 30 47 — 30 —
Backwash 2 (minutes) 3 3 3 2
Capacity (grains) @
salt (lb)
26,700 @
6.2 lb
26,700 @
6.2 lb
38,700 @
9.6 lb
23,100 @
6.2 lb
— — —
#4 Salt Setting
8
Backwash 1 (minutes) 1 1 1
7
— 4
7
— — —
Brine/Rinse (minutes) 45 45 60 — 45 —
Backwash 2 (minutes) 3 3 3 2
Capacity (grains) @
salt (lb)
32,500 @
9.5 lb
32,500 @
9.5 lb
49,300 @
14.4 lb
30,000 @
9.3 lb
— — —
1
Models 63MAQ, 63BEQ, 63MXQ, 62AMQ and 62APQ are certified by
WQA. All other models are not tested or certified by WQA
2
Municipally supplied chlorinated water only.
3
NA, See Mode 1 Setting Chart.
4
Model has no backwash flow control button or retainer. Must have a
minimum of 7 gpm @ 30 psi available for proper backwash. See Mode
1 Setting Chart.
5
Calcite will add additional hardness to water before softening.
6
If iron is present in water supply, use salt setting #3 or #4.
7
If iron is present in the water supply, set Backwash 1 to 7 minutes.
8
Do not use this salt setting in California.
Page view 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 51 52

Comments to this Manuals